Radiopharmaceuticals
| 6: METHOD FOR CONCENTRATING 99mTc
GENERATOR ELUATE (For 99mTc-technegas preparation) (Merseyside And Cheshire Radiopharmacy Services). |
|
| Materials Required | |
| 1 x Onguard -AG column (Dionex Ltd) | |
| 1 X BondElut SAX column (Jones Chromatography) | |
| 1 x BondElut adapter (Jones Chromatography) | |
| Water for injection | |
| Ethanol | |
| Sodium Chloride 5% solution | |
| Nitrogen filled vial | |
| 2 x 21g (green) needles | |
| 1 x 23g (blue) needle | |
| 1 x 1ml syringe | |
| 3 x 5ml syringes | |
| 1ml and 5ml syringe shields | |
| lead pot | |
| 99mTc generator eluate. | |
| Method | |
| 1. | Wash Onguard-AG column with 5ml water for injections. |
| 2. | Wash BondElut SAX column with 3ml ethanol, followed by 3ml water for injections. |
| 3. | Connect Onguard-AG column to BondElut-SAX column using a BondElut adapter.
(MAKE SURE THE CONNECTIONS ARE TIGHT) |
| 4. | Place the lower, BondElut SAX column in a suitable lead shield. |
| 5. | Pass 5ml of 99mTcO4- generator eluate (in a shielded syringe) through the column system, followed by 2ml water for injections. Pass slowly (5ml/min). |
| 6. | Then pass 5ml of air through the system. Use the syringe formerly holding water for injections. |
| 7. | Run effluents to waste. |
| 8. | Disconnect Onguard-AG column and discard. |
| 9. | Fit BondElut-SAX column with green needle (21g). Fit a sterile nitrogen filled vial with a bleed needle (23g) and place in a lead shield. |
| 10. | Pierce septum of N2 vial with BondElut SAX column/needle. |
| 11. | Elute column with 1ml sodium chloride 5%, collecting eluate in vial. |
| 12. | Pass through column 2ml air to ensure maximum extraction of activity. |
| 13. | Calibrate product, label and examine with TLC, if necessary. (Si-gel, n-butanol/acetic acid/water 3:2:3) |
------------------------------- |